Search results for "frequency [modulation]"
showing 10 items of 569 documents
Carotid intima-media thickness measurement through semi-automated detection software and analysis of vascular walls
2013
AIM: The aim of the present study was to compare the semi-automatic measurement of carotid intima thickness (RFQIMT - Esaote, Italy), with the conventional method. METHODS: We enrolle 81 patients, mean age 46 years ±15, with no history of cardio-cerebrovascular events and we assessed the traditional cardiovascular risk factors. We examined the IMT of the common carotid artery with manual and RFQIMT method (based on the "Radio Frequency" signal), according to the ASE protocol. RESULTS: Semi-automatic measurement was on average lower than manual measurement (617 μm ±191 vs. 676 μm ± 222) with a statistically significant difference (P<0.01). In agreement with manual measurements, the values of…
Effect of undersized drilling on the stability of immediate tapered implants in the anterior maxillary sector. A randomized clinical trial.
2020
Background To evaluate the effect of undersized drilling on the primary and secondary stability of immediate implants placed in the anterior maxilla. Material and Methods A comparative randomized clinical trial was carried out in 30 healthy adults. Thirty tapered implants, 16 involving conventional drilling and 14 undersized drilling, were placed immediately after anterior maxillary tooth removal. Insertion torque and implant stability assessed by resonance frequency analysis (RFA) were evaluated at three different timepoints: at implant placement and 6 and 12 weeks post-implantation. The results were compared using parametric statistical tests. Results All implants showed adequate stabilit…
Imaging findings of liver resection using a bipolar radiofrequency electrosurgical device—Initial observations
2010
Abstract Objective To assess contrast-enhanced US (CEUS), computed tomography (CT) and magnetic resonance (MR) imaging findings and serial changes of the treated area at follow-up in patients who underwent liver resection using a bipolar radiofrequency electrosurgical device. Methods Imaging findings of 27 patients with resected hepatocellular carcinomas (HCCs) ( n = 24) and metastases ( n = 3) (mean size: 2.6 cm), were retrospectively evaluated. Two readers assessed: the (a) presence, (b) thickness, (c) shape and (d) echogenicity (CEUS)/attenuation (CT)/signal intensity (MR imaging) at coagulated site and the (e) presence of residual tumor of the bipolar radiofrequency electrosurgical de…
Changes in Alcohol Consumption Pattern Based on Gender during COVID-19 Confinement in Spain
2021
(1) The goal of this study was to analyze the prevalence and pattern of alcohol consumption (frequency of consumption, average daily consumption, and risky consumption) before and during confinement due to the coronavirus disease (COVID-19) in the adult population and based on gender. (2) Methods: Data from 3779 individuals were collected via a set of online surveys. The AUDIT alcohol consumption questions (AUDIT-C) were used to measure the frequency of consumption, the average daily consumption, intensive consumption, risky consumption, and standard drink units. (3) Results: During confinement, the prevalence of alcohol consumption declined in both males and females, but only intensive con…
The location of the tibial accelerometer does influence impact acceleration parameters during running
2016
Tibial accelerations have been associated with a number of running injuries. However, studies attaching the tibial accelerometer on the proximal section are as numerous as those attaching the accelerometer on the distal section. This study aimed to investigate whether accelerometer location influences acceleration parameters commonly reported in running literature. To fulfil this purpose, 30 athletes ran at 2.22, 2.78 and 3.33 m · s–1 with three accelerometers attached with double-sided tape and tightened to the participants’ tolerance on the forehead, the proximal section of the tibia and the distal section of the tibia. Time-domain (peak acceleration, shock attenuation) and frequency-doma…
Comparison of implant primary stability between maxillary edentulous ridges receiving intramembranous origin block grafts
2012
Purpose: The purposes of the present study were: to compare the resonance frequency analysis (RFA) values of implant placed in either ramus or calvaria block grafts; and to determine if implant diameter influences RFA implant stability quotient (ISQ) value. Material and Methods: This was a retrospective study that included 16 consecutives healthy patients treated with autogenous onlay block grafts for horizontal bone reconstruction in maxilla. Ten ramus and ten calvaria block graft treated patients were selected and compared. Results: Totally, 59 implants were placed, 35 (59.3%) were placed on the calvaria bone grafts and the remaining 24 (40.7%) were on the ramus bone graft. Of all the imp…
Radiofrequency treatment of cervicogenic headache
2010
Objectives: In the clinical management of facial pain, a possible cervical origin must be considered. A clinical exploration is therefore essential. The disorder originates in the intimate connections between the cranial portion of the spinal cord and the trigeminal system. Although solid evidence supporting the use of radiofrequency (RF) treatment is lacking, it remains one of the management options to be taken into account. The present study evalu - ates the efficacy of RF in application to cervicogenic headache. Study design: We present three cases of severe facial pain arising from different cervical structures. Results: In two cases the pain originated in cervical roots C2 and C3, whil…
Time and frequency analysis of the static balance in young adults with Down syndrome
2010
The main objective of this study is to understand the differences in equilibrium control between normal subjects and those with Down syndrome. A total of 54 subjects participated voluntarily, divided into control group and Down syndrome group. The equilibrium of the subjects was tested under two conditions: bipedal support with eyes open and closed. The signals were analyzed in a time and frequency domain. The statistical parameters selected (i.e., RMS distance, mean velocity, mean frequency and sway area) to analyze the behavior of the center of pressures (CoP) are calculated employing the result of the combination of the time series data in both directions (i.e. resultant distance). In or…
Effect of implant macro-design on primary stability: A prospective clinical study
2016
Background Implant restorations have become a high predictable treatment option. Several caracteristics such as surgical technique and implant design can influence the treatment outcomes. The aim of the present study was to evaluate the influence of implant macro-design on primary stability measured with resonance frequency analysis (RFA) and insertion torque (IT). Material and Methods A total of 47 implants divided in two groups: Test group (TI): 22 Tapered MIS® Seven implants; Control group (CI): 25 cylindrical Astra® Osseospeed implants. All implants were inserted following the manufacturers’ standard protocols. Implant primary stability was measured at the moment of implant placement by…
Evaluation of Physiological Parameters on Discomfort Glare Thresholds Using LUMIZ 100 Tool
2021
Purpose To assess the links between discomfort glare sensitivity and physiological factors such as eye biometry, refraction, skin phototype, age, and gender among a large sample of healthy human subjects. Methods A total of 489 participants who were 20 to 70 years old (241 men, 248 women) underwent discomfort glare threshold measurements via the LUMIZ 100. Eye biometry and optical quality were measured using a Zeiss IOLMaster 700 biometer and i.Profiler aberrometer. Iris color, skin tone, age, gender, eyeglasses use, chronotype, fatigue level, self-evaluation of light sensitivity, and time spent outdoors were determined. Statistical analysis was carried out using nonparametric Mann–Whitney …